Very small fog particulates present on the surface of top coating.


Causes Prevention
wrong choice of thinners for the conditions of application, insufficient protection of noncoated surface areas, poor functioning of coating cabin. use hardener and solvent in accordance with actual temperature and the size of the coated object, carefully protect noncoated areas, ensure appropriate ventilation inside the coating cabin.

Repair

  • Mat and polish.

Overspray
  • Overspray